Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : SINOMATIC
Model Number : PD-132
Certification : CE/ ISO
Place of Origin : Shenzhen, China.
MOQ : Sample order accepted
Price : negotiable
Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability : 3,0000pcs per month
Delivery Time : 2-5 working days after payment received
Packaging Details : Carton/Plywood box/Pallet
Reaction time : 100ms
Voltage available : 230VAC , 115V AC, 24V DC/AC, 12VDC/AC
Loop connection wiring : Maximum length 200 meters Twisted at least 20 times per meter
Operating temperature : -20°C to +65°C
sensitivity : 4 levels
Pacakge : Carton
CE Approved Parking Vehicle Access Control Loop Detector Model PD132
PRODUCT DESCRIPTION
Loop Detectors are used with vehicle detection loops to create an inductance from a magnetic field to sense
vehicular traffic and increase access control. Loop wire is buried underground beneath a road or driveway and
are connected to inductive loop vehicle detectors to detect the presence of a vehicle. They are most commonly
used under roadways to detect vehicles stopped at traffic lights.
Operating Guide
The detector must be installed in a convenient weatherproof location as close to the loop as possible.
WARING:
1) This unit must be earthed.
2) Installation and operation by service professional only.
3) Disconnect power before working on this unit.
A correct loop configuration and detector installation will ensure a successful inductive loop
detection system.
Technical parameters of Loop Detector
Main Features:
1) Reset Switch : The reset switch enables the detector to be manually reset during commissioning and testing.
This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be energized for 1 Second
or 0.5 Seconds ;
3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a vehicle or when the
vehicle leaves the loop ;
4) Sensitivity Boost : This feature sets the undetect level to maximum sensitivity and is used to prevent loss of
detection of high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are available on the switches to allow flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available to prevent cross-talk between adjacent loops ;
7) Filter Option : This option is used to provide a delay between detection of the vehicle and switchiing of the output
relay . This relay is normally used to prevent false detection of small or fast moving objects ;
8) Permanent Presence Option : This feature ensure detection of the vehicle will be maintained when the vehicle is
parked over the loop for extended periods .
![]() |
100ms CE Access Control Loop Detector Model PD132 20m Wiring For Vehicle Images |